Refine Your Search

Topic

Author

Search Results

Technical Paper

Mechanisms of Traumatic Rupture of the Aorta and Associated Peri-isthmic Motion and Deformation

2008-11-03
2008-22-0010
This study investigated the mechanisms of traumatic rupture of the aorta (TRA). Eight unembalmed human cadavers were tested using various dynamic blunt loading modes. Impacts were conducted using a 32-kg impactor with a 152-mm face, and high-speed seatbelt pretensioners. High-speed biplane x-ray was used to visualize aortic motion within the mediastinum, and to measure deformation of the aorta. An axillary thoracotomy approach was used to access the peri-isthmic region to place radiopaque markers on the aorta. The cadavers were inverted for testing. Clinically relevant TRA was observed in seven of the tests. Peak average longitudinal Lagrange strain was 0.644, with the average peak for all tests being 0.208 ± 0.216. Peak intraluminal pressure of 165 kPa was recorded. Longitudinal stretch of the aorta was found to be a principal component of injury causation. Stretch of the aorta was generated by thoracic deformation, which is required for injury to occur.
Technical Paper

Biomechanical Assessment of a Rear-Seat Inflatable Seatbelt in Frontal Impacts

2011-11-07
2011-22-0008
This study evaluated the biomechanical performance of a rear-seat inflatable seatbelt system and compared it to that of a 3-point seatbelt system, which has a long history of good real-world performance. Frontal-impact sled tests were conducted with Hybrid III anthropomorphic test devices (ATDs) and with post mortem human subjects (PMHS) using both restraint systems and a generic rear-seat configuration. Results from these tests demonstrated: a) reduction in forward head excursion with the inflatable seatbelt system when compared to that of a 3-point seatbelt and; b) a reduction in ATD and PMHS peak chest deflections and the number of PMHS rib fractures with the inflatable seatbelt system and c) a reduction in PMHS cervical-spine injuries, due to the interaction of the chin with the inflated shoulder belt. These results suggest that an inflatable seatbelt system will offer additional benefits to some occupants in the rear seats.
Technical Paper

Factors Associated With Abdominal Injury in Frontal, Farside, and Nearside Crashes

2010-11-03
2010-22-0005
The NASS-CDS (1998-2008) and CIREN datasets were analyzed to identify factors contributing to abdominal injury in crash environments where belt use and airbag deployment are common. In frontal impacts, the percentage of occupants sustaining abdominal injury is three times higher for unbelted compared to belted front-row adult occupants (p≺0.0001) at both AIS2+ and AIS3+ injury levels. Airbag deployment does not substantially affect the percentage of occupants who sustain abdominal injuries in frontal impacts (p=0.6171), while belt use reduces the percentage of occupants sustaining abdominal injury in both nearside and farside crashes (p≺0.0001). Right-front passengers in right-side impacts have the highest risk (1.91%) of AIS 3+ abdominal injury (p=0.03). The percentage of occupants with AIS 3+ abdominal injuries does not vary with age for frontal, nearside, or farside impacts.
Technical Paper

The Tolerance of the Human Hip to Dynamic Knee Loading

2002-11-11
2002-22-0011
Based on an analysis of the National Automotive Sampling System (NASS) database from calendar years 1995-2000, over 30,000 fractures and dislocations of the knee-thigh-hip (KTH) complex occur in frontal motor-vehicle crashes each year in the United States. This analysis also shows that the risk of hip injury is generally higher than the risks of knee and thigh injuries in frontal crashes, that hip injuries are occurring to adult occupants of all ages, and that most hip injuries occur at crash severities that are equal to, or less than, those used in FMVSS 208 and NCAP testing. Because previous biomechanical research produced mostly knee or distal femur injuries, and because knee and femur injuries were frequently documented in early crash investigation data, the femur has traditionally been viewed as the weakest part of the KTH complex.
Technical Paper

Estimating Infant Head Injury Criteria and Impact Response Using Crash Reconstruction and Finite Element Modeling

2002-11-11
2002-22-0009
A combination of finite element modeling and sled test reconstruction of real-world infant head injury scenarios has been used to investigate infant head impact response and tolerance to skull fracture. Studying the role of cranial sutures on infant skull response was of particular interest. The specific injury scenarios selected for reconstruction involved infants in rear-facing child restraint systems (CRS) who sustained skull fractures and brain injuries from deploying passenger-side frontal airbags. Approximations of the loading conditions for three injury cases, as well as estimates of loading conditions not expected to result in head injury, were produced in the laboratory. A finite element model (FEM) of a six-month-old infant head was developed using available material properties and humanlike geometry. The infant head FEM was used to simulate different injury and no-injury loading conditions based on CRS response data from the reconstruction tests.
Technical Paper

Effects of Hip Posture on the Frontal Impact Tolerance of the Human Hip Joint

2003-10-27
2003-22-0002
… The pattern of left- and right-side hip injuries to front-seat occupants involved in offset and angled frontal crashes suggests that hip posture (i.e., the orientation of the femur relative to the pelvis) affects the fracture/dislocation tolerance of the hip joint to forces transmitted along the femur during knee-to-knee-bolster loading in frontal impacts. To investigate this hypothesis, dynamic hip tolerance tests were conducted on the left and right hips of 22 unembalmed cadavers. In these tests, the knee was dynamically loaded in the direction of the long axis of the femur and the pelvis was fixed to minimize inertial effects. Thirty-five successful hip tolerance tests were conducted. Twenty-five of these tests were performed with the hip oriented in a typical posture for a seated driver, or neutral posture, to provide a baseline measure of hip tolerance. The effects of hip posture on hip tolerance were quantified using a paired-comparison experimental design.
Technical Paper

Mechanical Properties and Anthropometry of the Human Infant Head

2004-11-01
2004-22-0013
The adult head has been studied extensively and computationally modeled for impact, however there have been few studies that attempt to quantify the mechanical properties of the pediatric skull. Likewise, little documentation of pediatric anthropometry exists. We hypothesize that the properties of the human pediatric skull differ from the human adult skull and exhibit viscoelastic structural properties. Quasi-static and dynamic compression tests were performed using the whole head of three human neonate specimens (ages 1 to 11 days old). Whole head compression tests were performed in a MTS servo-hydraulic actuator. Testing was conducted using nondestructive quasi-static, and constant velocity protocols in the anterior-posterior and right-left directions. In addition, the pediatric head specimens were dropped from 15cm and 30cm and impact force-time histories were measured for five different locations: vertex, occiput, forehead, right and left parietal region.
Technical Paper

Development of Anthropometric Specifications for the Six-Year-Old OCATD

2001-03-05
2001-01-1057
Advanced airbag systems use information from a variety of sensors to tune the airbag performance for crash severity and occupant characteristics. A new family of Occupant Classification ATDs (OCATD) have been developed for use in the design and testing of advanced airbag systems. This paper describes the development of anthropometric standards for an OCATD that represents a typical six-year-old child. Detailed analyses of existing child anthropometry databases were conducted to develop reference dimensions. A child who closely matched the reference dimensions was measured in a variety of conditions. A custom molded measurement seat was constructed using foam-in-place seating material. The surface of the child's body was scanned as he sat in the custom seat, and the three-dimensional locations of body landmarks defining the skeleton position were recorded.
Technical Paper

A New Database of Child Anthropometry and Seated Posture for Automotive Safety Applications

2005-04-11
2005-01-1837
This paper presents a laboratory study of body dimensions, seated posture, and seatbelt fit for children weighing from 40 to 100 lb (18 to 45 kg). Sixty-two boys and girls were measured in three vehicle seats with and without each of three belt-positioning boosters. In addition to standard anthropometric measurements, three-dimensional body landmark locations were recorded with a coordinate digitizer in sitter-selected and standardized postures. This new database quantifies the vehicle-seated postures of children and provides quantitative evidence of the effects of belt-positioning boosters on belt fit. The data will provide guidance for child restraint design, crash dummy development, and crash dummy positioning procedures.
Technical Paper

Anthropometry of U.S. Infants and Children

1975-02-01
750423
This report presents the results of a three-year study designed to collect analyze, and reduce selected anthropometric data on 4027 infants and children representative of the current U.S. population ranging in age from newborn to 12 years of age. Since the major purpose was to provide basic measurement data most useful and critical to consumer product design, regulatory consideration, or other direct applications, 12 of the 41 measurements taken were applied measurements which have not been previously available. As an example of the direct application to product design, measurement of buttock depth on 3-to 6-month-old infants provided an objective basis for establishment of crib interslat distances. A substantial portion of the study involved the design, fabrication, development, and testing of a new generation of anthropometric measuring devices which transmit measurement signals to a portable mini-computer data acquisition system or to a set of readout meters.
Technical Paper

PMHS Impact Response in 3 m/s and 8 m/s Nearside Impacts with Abdomen Offset

2013-11-11
2013-22-0015
Lateral impact tests were performed using seven male post-mortem human subjects (PMHS) to characterize the force-deflection response of contacted body regions, including the lower abdomen. All tests were performed using a dual-sled, side-impact test facility. A segmented impactor was mounted on a sled that was pneumatically accelerated into a second, initially stationary sled on which a subject was seated facing perpendicular to the direction of impact. Positions of impactor segments were adjusted for each subject so that forces applied to different anatomic regions, including thorax, abdomen, greater trochanter, iliac wing, and thigh, could be independently measured on each PMHS. The impactor contact surfaces were located in the same vertical plane, except that the abdomen plate was offset 5.1 cm towards the subject.
Technical Paper

Response and Tolerance of Female and/or Elderly PMHS to Lateral Impact

2014-11-10
2014-22-0015
Eight whole fresh-frozen cadavers (6 female, 2 male) that were elderly and/or female were laterally impacted using UMTRI's dual-sled side-impact test facility. Cadavers were not excluded on the basis of old age or bone diseases that affect tolerance. A thinly padded, multi-segment impactor was used that independently measured force histories applied to the shoulder, thorax, abdomen, greater trochanter, iliac wing, and femur of each PMHS. Impactor plates were adjusted vertically and laterally toward the subject so that contact with body regions occurred simultaneously and so that each segment contacted the same region on every subject. This configuration minimized the effects of body shape on load sharing between regions. Prior to all tests, cadavers were CT scanned to check for pre-existing skeletal injuries. Cadavers were excluded if they had pre-existing rib fractures or had undergone CPR.
Technical Paper

New Concepts in Vehicle Interior Design Using ASPECT

1999-03-01
1999-01-0967
The ASPECT (Automotive Seat and Package Evaluation and Comparison Tools) program developed a new physical manikin for seat measurement and new techniques for integrating the seat measurements into the vehicle design process. This paper presents an overview of new concepts in vehicle interior design that have resulted from the ASPECT program and other studies of vehicle occupant posture and position conducted at UMTRI. The new methods result from an integration of revised versions of the SAE seat position and eyellipse models with the new tools developed in ASPECT. Measures of seat and vehicle interior geometry are input to statistical posture and position prediction tools that can be applied to any specified user population or individual occupant anthropometry.
Technical Paper

Tensile Properties of the Human Muscular and Ligamentous Cervical Spine

2000-11-01
2000-01-SC07
Tensile neck injuries are amongst the most serious cervical injuries. However, because neither reliable human cervical tensile tolerance data nor tensile structural data are currently available, the quantification of tensile injury risk is limited. The purpose of this study is to provide previously unavailable kinetic and tolerance data for the ligamentous cervical spine and determine the effect of neck muscle on tensile load response and tolerance. Using six male human cadaver specimens, isolated ligamentous cervical spine tests (occiput - T1) were conducted to quantify the significant differences in kinetics due to head end condition and anteroposterior eccentricity of the tensile load. The spine was then separated into motion segments for tension failure testing. The upper cervical spine tolerance of 2400 ± 270 N (occiput- C2) was found to be significantly greater (p< 0.01) than the lower cervical spine tolerance of 1780 ± 230 N (C4-C5 and C6-C7 segments).
Technical Paper

Facial, Periorbital and Ocular Injuries Related to Steering-Wheel Airbag Deployments

1997-02-24
970490
To determine the frequency of facial injuries from steering-wheel airbag deployments, 540 consecutive steering-wheel airbag deployments, investigated by the University of Michigan Transportation Research Institute (UMTRI) personnel, were reviewed. About 1 in 3 drivers sustain an injury to the face. Injuries to the area surrounding the eye (periorbital) or to the eyeball (ocular) rarely occur. The frequencies of facial or ocular injuries are the same for belted and unbelted drivers. Drivers of short stature had a higher frequency of facial injury. Females sustained ocular injuries more frequently than males. Untethered airbags were not overly involved in drivers with an ocular injury. No specific make or model car were overly represented in the ocular injury cases.
Technical Paper

A Laboratory Technique for Assessing the Skin Abrasion Potential of Airbags

1993-03-01
930644
In recent investigations of airbag deployments, drivers h v c reported abrasions to the face, neck, and forearms due to deploying airbags, A study of the airbag design and deployments parameters affecting the incidence and severity of abrasions caused by driver-side airbags has led to the development of a laboratory test procedure to evaluate the potential of an airbag design m cause skin injury This report describes the procedure, which is based an static deployments of airbags into a cylindrical lest fixture. The target area is covered with a material that responds to abrasion-producing events in a manner related to human skin tolerance. Test results show excellent correlation with abrasion injuries produced by airbag deployments into the skin of human volunteers.
X